aero365 NonWoven365

aero365 · Battery Applications

The thinnest part of a
battery module does
the hardest work.

Between two prismatic cells sits a gap of one to two millimetres. It has to insulate against thermal propagation, absorb cell swelling and hold up when a cell fails. aero365 is engineered for exactly that gap.

< 25 mW/mK Thermal conductivity
1–3 mm Single layer thickness
UL94 V0 above 800 °C Flammability
~90 % Inorganic content

01 — Assembled

A prismatic battery module

Five cells, two compression plates, one enclosure. Everything that matters for thermal safety happens in the gaps you cannot see.

02 — Opened

The gap is the problem

One to two millimetres between cells. Too thin for conventional insulation, yet it has to stop heat, take up swelling and survive fire.

03 — Revealed

aero365 sits in that gap

Silica aerogel in a wet-laid nonwoven. Below 25 mW/mK thermal conductivity, around 90 % inorganic, 1 to 3 mm thin.

04 — One layer

Three jobs at once

Thermal barrier, compression pad and fire protection — thermoformable into complex three-dimensional geometries, with minimal dust during processing.

05 — Inside the sheet

Wet-laid, not dry-laid

Staple fibres suspended in water and deposited on a screen — the same principle as papermaking. That is what produces the fibre homogeneity a dry-laid web cannot reach.

Schematic representation · cell and layer shown in scale

aero365 in the battery module

Aerogel insulation paper as a cell-to-cell barrier: below 25 mW/mK in 1–3 mm, around 90 % inorganic, UL94 V0 above 800 °C, compressible with good shape recovery.

Why it works

One layer, three functions

01

Thermal barrier

Below 25 mW/mK at room temperature — in a single layer of 1 to 3 mm. Inter-cell spacing in prismatic modules is typically 1 to 2 mm, which rules out most insulation materials before the evaluation even starts.

02

Compression pad

Cells swell over their service life. aero365 is compressible with good shape recovery, so it absorbs that movement instead of transferring it into the module structure.

03

Fire protection

Approximately 90 % inorganic and non-combustible, classified UL94 V0 above 800 °C. The barrier stays a barrier when a neighbouring cell fails.

Technical data

aero365 at a glance

Thermal conductivity
< 25 mW/mK (at room temperature)
Thickness (single layer)
1–3 mm, customised thickness available
Flammability
Non-flammable (UL94 V0) above 800 °C
Compressibility
Excellent, with good shape recovery
Electric insulation
Very low dielectric constant, excellent insulating properties
Geometry
Complex three-dimensional shapes achievable
Forming methods
Thermoformable & heat sealable
Dust contamination
Minimal during processing

Let's Create

Areal weight, thickness and geometry are adapted to the module, not the other way around. Send us your packaging envelope and temperature target — we will tell you what is achievable.

Phoenix Non Woven GmbH & Co. KG · ISO 9001 certified · TÜV SÜD